CCELL® HEATING TECHNOLOGY

Four CCELL® ceramic heating platforms, compared.

SE, EVOMAX, CCELL 3.0 and HeRo are each built for a different range of oils. See how CCELL’s heating platforms compare, and which one to start with for yours.

  • 2016CCELL ceramic core launched
  • 499Patent applications
  • 4Heating platforms
  • 30%Lower peak temp · 3.0*

CCELL has applied for 499 patents worldwide; 247 have been granted. *CCELL 3.0 peak atomization temperature compared with conventional heating cores, per CCELL.

SE white porous ceramic heating core
SE
EVOMAX dark porous ceramic heating core
EVOMAX
HeRo heating core with glowing heating zones
HeRo
CCELL 3.0 clean white porous ceramic core with golden heating mesh
CCELL 3.0
SE · EVOMAX · HeRo · CCELL 3.0
WHY IT MATTERS

Why Heating Technology Matters

The heating core decides how your oil heats. Match the wrong core to your oil and it shows up as burnt hits, clogged carts, wasted oil and returns.

CCELL launched its ceramic heating core in 2016. Each platform below is tuned for a different range of oils. Start with the one built for yours, then confirm the fit with samples.

WHAT A MISMATCH COSTS
  • Burnt taste
  • Clogged units
  • Wasted oil
  • Returns
WHAT TO TEST IN SAMPLES
  • Vapor consistency
  • Residual oil
  • Leakage and clogging

Need help matching your oil to the right platform?

Request Samples→

SE PLATFORM

CCELL® SE Heating Technology

SE is CCELL’s original porous ceramic core, with thin walls for fast heating. It’s built for distillate and is the value choice for distillate cartridges and all-in-ones.

  • VISCOSITY10K–700K cPRecommended range
  • HEATINGSE Ceramic Coil
  • BEST FORDistillate
  • FORMATCartridge / AIO
OIL COMPATIBILITY
  • ✓ Distillate
  • — Live Resin: choose EVOMAX
  • — Live Rosin: choose EVOMAX or HeRo
  • — Liquid Diamonds: choose EVOMAX or 3.0
CCELL heating platform illustration
DRAG TO ROTATE
SE HEATING CORE
POROUS CERAMIC · THIN WALL
EVOMAX PLATFORM

CCELL® EVOMAX Heating Technology

EVOMAX pairs optimized ceramic walls with an even pore distribution to keep thick oils flowing. It’s CCELL’s all-oil platform — distillate, live resin, live rosin and liquid diamonds — and the enlarged-airway version handles oils up to 5M cP.

  • VISCOSITY10K–2M cPUp to 5M cP with enlarged airway
  • HEATINGPorous CeramicOptimized walls and pores
  • APPLICATIONS4 Oil CategoriesDistillate to liquid diamonds
  • RESISTANCE1.7 ΩStandard TH2/M6T-EVOMAX; 1.4 Ω is a customization option

Ceramic EVOMAX adds a ceramic center post and ceramic mouthpiece to a borosilicate glass tank. CCELL calls it a full-ceramic design, built to keep oil away from heavy metals.

OIL COMPATIBILITY
  • ✓ Distillate
  • ✓ Live Resin
  • ✓ Live Rosin
  • ✓ Liquid Diamonds
CCELL heating platform illustration
DRAG TO ROTATE
EVOMAX HEATING CORE
OPTIMIZED WALLS & PORES
FROM THE CCELL® EVOMAX LAUNCH FILE
DRAG
CCELL EVOMAX heating element, CCELL illustration
EVOMAX · 01
CCELL EVOMAX oil compatibility, CCELL illustration
EVOMAX · 02
CCELL EVOMAX ceramic walls and pores, CCELL illustration
EVOMAX · 03
CCELL EVOMAX heat distribution, CCELL illustration
EVOMAX · 04
CCELL EVOMAX heat-distribution and terpene-vaporization illustration
EVOMAX · 05
CCELL EVOMAX performance, CCELL illustration
EVOMAX · 06
3.0 BIO-HEATING PLATFORM

CCELL® 3.0 Bio-Heating Technology

CCELL 3.0 pairs 3D Stomata porous ceramic with a Nexus Film heating layer in a cotton-free core, set in a postless tank. CCELL reports a 30% lower peak atomization temperature than conventional heating cores, to preserve terpenes.

  • VISCOSITY10K–4.5M cPRecommended range
  • HEATING3D Stomata CeramicWith Nexus Film heating
  • PEAK TEMPERATURE30% Lower*Vs. conventional cores
  • CORECotton-Free, Postless

*Live resin and live rosin work on 3.0 when the oil is well filtered and low in fats and lipids.

OIL COMPATIBILITY
  • ✓ Distillate
  • ○ Live Resin: well-filtered*
  • ○ Live Rosin: well-filtered*
  • ✓ Liquid Diamonds
CCELL heating platform illustration
DRAG TO ROTATE
CCELL 3.0 HEATING CORE
3D STOMATA CERAMIC
INSIDE THE 3.0 CORE · CCELL® IMAGERY
DRAG
CCELL 3.0 3D Stomata ceramic
3D STOMATA CERAMIC
CCELL 3.0 VeinMesh interlock structure
MESH INTERLOCK STRUCTURE
CCELL 3.0 fusion structure detail
FUSION STRUCTURE DETAIL
CCELL 3.0 Stomata core vapor close-up
STOMATA CORE · VAPOR
CCELL 3.0 Nexus film, smooth inhale
NEXUS FILM · SMOOTH INHALE
CCELL 3.0 leak and clog prevention
LEAK & CLOG PREVENTION
CCELL 3.0 molecular highway
MOLECULAR HIGHWAY
CCELL 3.0 ceramic vapor, pure hit
CERAMIC CORE · VAPOR
HeRo PLATFORM

CCELL® HeRo Heating Technology

HeRo is CCELL’s platform for live rosin. Partitioned atomization heats different zones of the core at different temperatures, and two oil pathways keep it fed. In HeRo devices, the airway is sealed off from the battery and electronics.

  • DESIGNED FORLive Rosin
  • HEATINGPartitioned Atomization
  • VISCOSITY10K–500K cPRecommended range
  • OIL PATHWAYSDualKeeps the core saturated

Find HeRo in the Rosin Bar — 0.5 mL with a metal body, or 1 mL postless with a thermoplastic body, both inhale-activated with USB-C — and in the Vision Box Elite.

CCELL heating platform illustration
DRAG TO ROTATE
HeRo HEATING CORE
PARTITIONED ATOMIZATION
FROM THE CCELL® ROSIN BAR & VISION BOX ELITE LAUNCH FILES
DRAG
CCELL Rosin Bar with HeRo heating, CCELL illustration
ROSIN BAR · 01
CCELL HeRo partitioned atomization, CCELL illustration
ROSIN BAR · 02
CCELL HeRo dual oil pathways, CCELL illustration
ROSIN BAR · 03
CCELL HeRo heating technology, Vision Box Elite launch file
HeRo · VISION BOX ELITE
VISCOSITY SPECTRUM

One scale. Four platforms.

Where each heating core works best, by oil viscosity. Select an oil to see which platforms fit it.

✓ Recommended○ Well-filtered oil only— Not recommended
SE10K–700K cP
EVOMAX10K–2M cPto 5M · enlarged airway
3.0 Bio-Heating10K–4.5M cP
HeRo10K–500K cP

Logarithmic scale. The dashed EVOMAX tail is the enlarged-airway version, rated 700K–5M cP and recommended above 2M cP. Ranges from CCELL.

*On CCELL 3.0, use well-filtered, high-purity live resin or rosin with low fat and lipid content. Viscosity changes with temperature, so compare readings taken the same way.

PLATFORM COMPARISON

Four CCELL® heating platforms, side by side.

PLATFORM 01SE 02EVOMAX 033.0 Bio-Heating 04HeRo
Heating Design Porous Ceramic Optimized Ceramic 3D Stomata Ceramic Partitioned Atomization
Viscosity Guidance* 10K–700K cP 10K–2M cP
Enlarged-airway option: 700K–5M
10K–4.5M cP 10K–500K cP
Distillate ✓ ✓ ✓ —
Live Resin — ✓ ○ —
Liquid Diamonds — ✓ ✓ —
Live Rosin — ✓ ○ ✓
Postless Design — — ✓ Rosin Bar 1 mL: yes
0.5 mL: center post
Cotton-Free Core — — ✓ —
Dual Oil Pathways — — — ✓
Isolated Airway Mini Tank Mini Tank / Vision Box — Rosin Bar / Vision Box Elite
Anti-Burn Feature — Vision Box — Vision Box Elite
510 Cartridge ✓ ✓ ✓ —
AIO Disposable ✓ ✓ ✓ ✓

✓ = Recommended / included○ = Well-filtered oil only— = Not recommended / not included

*See the viscosity chart for the full ranges. Isolated airway and anti-burn are device features, so the table names the devices that have them.

MATCH YOUR OIL

Match Your Oil to the Right Platform

Start with your oil. Here’s which CCELL heating platforms fit each one.

Formulation-dependent viscosity

Cannabis Distillate

SE, EVOMAX and 3.0 all handle distillate. SE is the value choice.

SEEVOMAX3.0
Formulation-dependent viscosity

Live Resin

EVOMAX handles live resin. 3.0 works with well-filtered resin.

EVOMAX3.0 · conditional
Formulation-dependent viscosity

Live Rosin

HeRo is built for live rosin, and EVOMAX handles it too. 3.0 works with well-filtered rosin.

EVOMAXHeRo3.0
Formulation-dependent viscosity

Liquid Diamonds

EVOMAX and 3.0 both handle liquid diamonds; 3.0’s lower peak temperature helps preserve terpenes.

EVOMAX3.0
NEXT STEP

Ready to Find the Right Hardware?

Request samples to test with your formulation, or browse our full product catalog.